Views: 0 Author: Site Editor Publish Time: 2026-01-12 Origin: Site
During low-speed operation,the self-reversing screw drive system may exhibit stick-slip motion—characterized by intermittent movement and uneven speed—which affects positioning accuracy and motion stability.

Poor Lubrication
Cause: Insufficient or degraded lubricant.
Solution: Clean regularly and replenish with dedicated screw grease (recommended: ISO VG68 grade oil).
Improper Preload
Cause: Preload too high or too low.
Solution: Re-adjust preload to the standard value (typically 5–10% of the rated dynamic load).
Assembly Issues
Cause: Excessive parallelism deviation between the screw and guide rails.
Solution: Inspect with a laser interferometer and realign (parallelism ≤ 0.02 mm/m).
Drive System Problems
Cause: Improper servo motor parameter settings.
Solution: Optimize servo gain parameters,especially speed loop gain.
Mechanical Wear
Cause: Wear of balls or raceways.
Solution: Inspect the recirculation channel for wear; replace the entire self-reversing screw assembly if necessary.
Preventive Measures
Implement a regular maintenance schedule (recommended: inspection every 2,000 operating hours).
Use high-quality dust protection devices (minimum IP54 rating).
Avoid prolonged operation at maximum rotational speed.
Note: For precision applications,installing a temperature compensation system is recommended to mitigate thermal deformation effects.